Components for Disconnect Boxes

AC and DC disconnect boxes allow the solar array power to be easily disconnected for emergencies or just general maintenance. They separate the generated power from systems and circuits downstream from the disconnect box. Disconnect boxes safely disconnect power generated by the solar arrays from downstream circuits.

Learn More

Results: 67
Select Image Part # Mfr. Description Datasheet Availability Pricing (EUR) Filter the results in the table by unit price based on your quantity. Qty. RoHS ECAD Model Series Product Type Current Rating Voltage Rating AC Voltage Rating DC Number of Poles Actuator Type Minimum Operating Temperature Maximum Operating Temperature Illuminated Packaging
Carling Technologies Circuit Breakers 20A TWO POLE FLAT ROCKER RED Non-Stocked
Min.: 10
Mult.: 10

C Circuit Breaker Supplementary Protector 20 A 277 VAC 80 VDC 2 Pole Rocker - 55 C + 85 C Non-Illuminated
Carling Technologies Circuit Breakers 30A TWO POLE FLAT ROCKER RED Non-Stocked
Min.: 10
Mult.: 10

C Circuit Breaker Supplementary Protector 30 A 277 VAC 80 VDC 2 Pole Rocker - 55 C + 85 C Non-Illuminated


Carling Technologies Circuit Breakers 60A ONE POLE Non-Stocked
Min.: 30
Mult.: 10

C Circuit Breaker Hydraulic Magnetic 60 A 120 VAC, 240 VAC 1 Pole Handle - 40 C + 85 C Non-Illuminated
Carling Technologies Circuit Breakers 20A 1 POLE Non-Stocked
Min.: 50
Mult.: 25

C Circuit Breaker Hydraulic Magnetic 20 A 480 VAC 150 VDC 1 Pole Handle - 40 C + 85 C Non-Illuminated
Carling Technologies Circuit Breakers 5 A ONE POLE Non-Stocked
Min.: 1
Mult.: 1

C Circuit Breaker Supplementary Protector 5 A 480 VAC 150 VDC 1 Pole Handle - 40 C + 85 C Non-Illuminated
Carling Technologies Circuit Breakers 10 A ONE POLE Non-Stocked
Min.: 30
Mult.: 10

C Circuit Breaker Supplementary Protector 10 A 480 VAC 150 VDC 1 Pole Handle - 40 C + 85 C Non-Illuminated
Carling Technologies Circuit Breakers 40 A ONE POLE Non-Stocked
Min.: 1
Mult.: 1

C Circuit Breaker Hydraulic Magnetic 40 A 240 VAC 1 Pole Handle - 40 C + 85 C Non-Illuminated Bulk
Carling Technologies Circuit Breakers 50 A ONE POLE Non-Stocked
Min.: 1
Mult.: 1

C Circuit Breaker Supplementary Protector 50 A 480 VAC 150 VDC 1 Pole Handle - 40 C + 85 C Non-Illuminated
Carling Technologies Circuit Breakers SPDT 0.110 DC SHORT Non-Stocked
Min.: 30
Mult.: 10

C Circuit Breaker Hydraulic Magnetic 30 A 80 VDC 1 Pole Handle - 40 C + 85 C Non-Illuminated
Carling Technologies Circuit Breakers Circuit Breaker Mag Hyd. 1Pole 15A 480V Non-Stocked
Min.: 25
Mult.: 1

C Circuit Breaker Hydraulic Magnetic 15 A 120 VAC, 240 VAC 1 Pole Handle - 40 C + 85 C Non-Illuminated
Carling Technologies Circuit Breakers SPDT 0.110 QC TERM CURRENT RATING 2.500 Non-Stocked
Min.: 30
Mult.: 10

C Circuit Breaker Hydraulic Magnetic 2.5 A 1 Pole Handle - 40 C + 85 C Non-Illuminated
Carling Technologies Circuit Breakers SPDT 0.110 QC TERM CURRNT RATING 30.000 Non-Stocked
Min.: 1
Mult.: 1

C Circuit Breaker Hydraulic Magnetic 30 A 1 Pole Handle - 40 C + 85 C Non-Illuminated
Carling Technologies Circuit Breakers 2 POLE W/OUT AUX SWITCH Non-Stocked
Min.: 30
Mult.: 10

C Circuit Breaker Hydraulic Magnetic 15 A 120 VAC, 240 VAC 2 Pole Handle - 40 C + 85 C Non-Illuminated
Carling Technologies Circuit Breakers 20A 2 PULL 220V Non-Stocked
Min.: 30
Mult.: 10

C Circuit Breaker Hydraulic Magnetic 20 A 240 VAC 2 Pole Handle - 40 C + 85 C Non-Illuminated
Carling Technologies Circuit Breakers 50 AMP SIGLE POLE CIRCUIT BRKR Non-Stocked Lead-Time 16 Weeks
Min.: 30
Mult.: 10

C Circuit Breaker Supplementary Protector 50 A 277 VAC 80 VDC 2 Pole Handle - 40 C + 85 C Non-Illuminated
Carling Technologies Circuit Breakers 5 A TWO POLE Non-Stocked
Min.: 30
Mult.: 10

C Circuit Breaker Supplementary Protector 5 A 277 VAC 80 VDC 2 Pole Handle - 40 C + 85 C Non-Illuminated
Carling Technologies Circuit Breakers 40 A TWO POLE Non-Stocked
Min.: 1
Mult.: 1

C Circuit Breaker Hydraulic Magnetic 40 A 240 VAC 2 Pole Handle - 40 C + 85 C Non-Illuminated
Carling Technologies Circuit Breakers 50 A TWO POLE Non-Stocked
Min.: 1
Mult.: 1

C Circuit Breaker Hydraulic Magnetic 50 A 277 VAC 80 VDC 2 Pole Handle - 40 C + 85 C Non-Illuminated Bulk
Carling Technologies Circuit Breakers Hydraulic/Magnetic Circuit Breaker Non-Stocked
Min.: 10
Mult.: 10

C Circuit Breaker Hydraulic Magnetic 50 A 277 VAC 80 VDC 2 Pole Handle - 40 C + 85 C Non-Illuminated
Carling Technologies Circuit Breakers 3 POLE 5 AMPS Non-Stocked
Min.: 10
Mult.: 5

C Circuit Breaker Supplementary Protector 5 A 277 VAC 80 VDC 3 Pole Handle - 40 C + 85 C Non-Illuminated
Carling Technologies Circuit Breakers 3 POLE 15 AMPS Non-Stocked
Min.: 30
Mult.: 10

C Circuit Breaker Supplementary Protector 15 A 277 VAC 80 VDC 3 Pole Handle - 40 C + 85 C Non-Illuminated
Carling Technologies Circuit Breakers 3 POLE 20 A Non-Stocked
Min.: 30
Mult.: 10

C Circuit Breaker Supplementary Protector 20 A 277 VAC 80 VDC 3 Pole Handle - 40 C + 85 C Non-Illuminated
Carling Technologies Circuit Breakers 3 PLOE 30 AMPS Non-Stocked
Min.: 30
Mult.: 10

C Circuit Breaker Hydraulic Magnetic 30 A 240 VAC 3 Pole Handle - 40 C + 85 C Non-Illuminated
Carling Technologies Circuit Breakers 3 POLE 40 AMPS Non-Stocked
Min.: 10
Mult.: 10

C Circuit Breaker Hydraulic Magnetic 40 A 240 VAC 3 Pole Handle - 40 C + 85 C Non-Illuminated
Carling Technologies Circuit Breakers 3 POLE 50 AMPS Non-Stocked
Min.: 30
Mult.: 10

C Circuit Breaker Supplementary Protector 50 A 277 VAC 80 VDC 3 Pole Handle - 40 C + 85 C Non-Illuminated